Gas leaks on distribution networks, meter sets, service lines and indoor piping in Pakistan are usually found the same way: someone walks the line with a handheld detector, picks up a trace of gas in parts per million, then follows it until the reading climbs and the leak can be pinpointed and classified (general). The instrument has to read very low concentrations for the search, high concentrations once the source is close, and the explosive limit for the safety call (general).
This note looks at the QED Metrex 2 Natural Gas Leak Detector from the Huberg range, a portable three-sensor instrument with PPM, %VOL and %LEL scales for leak survey and pinpointing. It covers what the published data says, how the three scales work in the field, how to look after the instrument and where it fits in Pakistani gas work. Figures come from the QED METREX2 User Manual (002), the QED Metrex 2 product page and the current Tetracon product page. General engineering advice is labelled as general, and nothing here goes beyond the published data. Tetracon (Pvt.) Ltd. is the sole authorized agent for QED Environmental Systems Ltd in Pakistan.
Why a three-scale leak detector
- Find, locate, classify. QED describes the Metrex 2 as designed for pre-localisation, localisation and classification of natural gas leaks (QED product page). The Tetracon product page lists natural gas leak detection and survey, and leak pinpointing (product page).
- Low and high concentrations in one instrument. The METREX2 has three measuring ranges, PPM, %VOL and %LEL, and three sensors: a semiconductor sensor, a pellistor pair and a volumetric thermal conductivity pair (QED user manual).
- It changes range for you. If 1 %VOL is reached while working in the PPM range, the instrument changes over to the volumetric range automatically (QED user manual), and QED lists automatic scaling to PPM / VOL / LEL as a benefit (QED product page).
- Outside and inside buildings. The METREX2 is intended for systematic survey of natural and town gas networks and for leak detection outside as well as inside buildings (QED user manual).
- Built for first responders. QED calls it ideal for first responder technicians handling suspected gas leaks, with a robust design and an easy to use interface (QED product page).
Metrex 2 at a glance
| Item | QED Huberg Metrex 2 (source) |
|---|---|
| Duty | Natural gas leak detection and survey; leak pinpointing; portable field instrument (product page) |
| Sensors | One semiconductor sensor, one pellistor pair and one volumetric thermal conductivity pair (QED user manual) |
| PPM scale | 0 to 9,900 ppm; the instrument starts in the PPM range after switch-on (QED user manual) |
| %VOL scale | 0 to 100 %; automatic change from PPM to VOL at 1 %VOL; manual return to PPM below 10,000 ppm (1 %) (QED user manual) |
| %LEL scale | Selected by holding the PPM/VOL button for more than 2 seconds; for CH4, 0-100 %LEL corresponds to 0-5 %VOL (QED user manual) |
| Gas calibration | CH4; optional LPG (C3H8) and/or city gas calibrations, selectable from the keypad in a gas-free area (QED user manual) |
| Alarms | Acoustic alarm (on at switch-on, can be muted) and optical alarm LED; thresholds adjustable in the PPM and VOL ranges (QED user manual) |
| Data memory | Optional: up to 500 readings stored in internal memory, downloadable to a PC through the serial port (QED user manual) |
| Start-up | Warm-up and auto calibration take about 1 minute; switch on in a gas-free place (QED user manual) |
| Zeroing | Auto zero button, usable only below 1,800 ppm (QED user manual) |
| Power | Rechargeable NiMH batteries, at least 8 hours of operation at 20 °C; recharge about 10 to 12 hours with the Huberg charger (QED user manual) |
| Pump | Built-in sampling with quick coupling for probes; optional pump-block feature stops measurement and shows "Poff" after about 4 seconds of continuous flow obstruction (QED user manual) |
| Hazardous area | Designed to comply with the ATEX directive (QED user manual); the Huberg brochure shows II 2G Ex ia d IIC T4 Gb (Huberg brochure) |
| Service | Annual service and calibration recommended, with a calibration certificate issued after checking and adjusting (QED user manual) |
The Tetracon product page lists the model as Metrex 2 with brand QED / Geotech / Huberg (product page). QED also notes that the Metrex instrument can localise water leaks where hydrogen is used as a tracer gas (QED product page); the user manual covers CH4 with optional LPG and city gas calibrations (QED user manual), so tell us if you need tracer-gas work and we will confirm the configuration with QED (general).
How the three scales work in the field
- Switch on clean. Hold one of the lower right buttons for at least three seconds; the display shows the serial number, the software version and "CAL" while it warms up and calibrates for about a minute, then goes to the PPM scale. Switching on must be done in a place free from gas (QED user manual).
- Search in PPM. The PPM range reads 0 to 9,900 ppm (QED user manual), the scale for tracing small concentrations along a pipe route or around a meter set (general).
- Close in on %VOL. At 1 %VOL the instrument changes to the volumetric scale by itself and lights the %VOL LED; going back to PPM is a manual button press and only works below 10,000 ppm (QED user manual).
- Make the safety call in %LEL. Holding the PPM/VOL button for more than 2 seconds selects the LEL scale; for methane 100 %LEL equals 5 %VOL (QED user manual).
- Alarms you can set. The alarm threshold can be viewed and changed from the keypad in both the PPM and VOL ranges, and the optical alarm LED still blinks above the limit even if the buzzer is muted (QED user manual).
- Record what you found. With the optional data registration, pressing the record button freezes the reading and stops the pump, and a third press stores it; up to 500 readings can be held and reviewed on the display before download (QED user manual).
Care, charging and calibration
- Charge in a safe area. Recharging and I/O connection must be carried out in safe environments, using only the Huberg charger supplied (QED user manual).
- Plan the charge. A full recharge takes about 10 to 12 hours; when the low-battery icon appears the instrument runs for 10 more minutes and then shows STOP (QED user manual). Charge overnight before a survey day (general).
- Do not over-charge, do not let it sit flat. Do not leave it on the charger longer than needed, and recharge at least every 4 weeks if it is not in use (QED user manual).
- Zero only in clean air. The auto zero works only below 1,800 ppm (QED user manual); zero away from the suspected leak (general).
- Keep the sample path clear. Probes connect at the quick coupling (QED user manual); a blocked probe or filter is the usual reason for a slow or missing reading (general), and the optional pump-block feature flags a continuous obstruction (QED user manual).
- Calibrate every year. QED recommends annual service and calibration by QED or an authorised service distributor, and regular checks with the HANDYGAS instrument depending on use (QED user manual). Opening the instrument by unauthorised personnel invalidates the certification (QED user manual).
Where it fits in Pakistan
- Gas distribution networks. Systematic survey of natural and town gas networks is the stated use (QED user manual), for example walking service lines and street mains in city networks (general).
- Meters, regulators and connections. Appendix A describes the instrument as a portable methane leak detector for searching leaks in meters, connections and the distribution network, and for personal safety (QED user manual).
- Industrial and commercial sites. Leak detection inside buildings is covered (QED user manual), for example gas trains on boilers, kitchens in hotels and hospitals, and plant-room piping (general).
- LPG users. The optional LPG (C3H8) calibration (QED user manual) suits sites that run on LPG rather than piped natural gas, which is common across Pakistan (general).
- Emergency response. QED positions the Metrex 2 for first responder technicians handling suspected gas leaks (QED product page); the %LEL scale helps decide whether an area needs to be cleared (general).
Related products
| Need | Product | Key point |
|---|---|---|
| Three-scale leak survey and pinpointing | QED Metrex 2 | PPM, %VOL and %LEL; semiconductor, pellistor and thermal conductivity sensors (QED user manual) |
| GPS-logged surveys with compliance reports | QED Metrex | 0-10,000 ppm, ATEX GPS and Bluetooth, PROSoft reporting, 10-hour battery, IP65 (product page) |
| Methane-only detection with no cross-gas readings | Huberg LASER One | TDLAS, 1 ppm to 100 %vol, T90 2.5 s, two-year factory calibration (product page) |
| Fixed detection in hazardous areas | Status Scientific FGD5/6-IR | Ex db infrared gas detector head (product page) |
For GPS-logged network surveys read our QED Metrex note, and for methane-only laser detection our LASER One note. Fixed and portable detectors are on the Gas Detection category page, with more in our selection guides, and the full QED range is on the QED Environmental Systems manufacturer page.
What to send with an enquiry
- The gas you need to detect: natural gas (methane), LPG, city gas, or hydrogen as a tracer gas.
- The job: network survey, meter and regulator checks, indoor leak checks, emergency response or plant maintenance.
- Whether you need to store readings and download them to a PC, and how many instruments.
- The probes you need for the sites you work on, and whether the instrument will be used in hazardous areas.
- Your calibration plan: in-house checks, annual service, and whether you need calibration certificates.
Send these to Tetracon and our engineers will confirm the right configuration, accessories and lead time. Our services team in Islamabad supports commissioning, training and calibration across Pakistan.
FAQ
What is the QED Metrex 2?
It is a portable Huberg natural gas leak detector for leak survey and pinpointing (product page), designed for pre-localisation, localisation and classification of natural gas leaks (QED product page).
What ranges does the Metrex 2 measure?
It has three scales: 0 to 9,900 ppm, 0 to 100 %VOL and %LEL, where for methane 100 %LEL equals 5 %VOL. It changes from PPM to %VOL automatically at 1 %VOL (QED user manual).
Which sensors are inside?
One semiconductor sensor, one pellistor pair and one volumetric thermal conductivity pair (QED user manual).
Can it detect LPG as well as natural gas?
The instrument is calibrated for CH4 and can optionally be supplied with LPG (C3H8) and/or city gas calibrations, selected from the keypad in a gas-free area (QED user manual).
Who supplies QED in Pakistan?
Tetracon (Pvt.) Ltd., Islamabad, is the sole authorized agent for QED Environmental Systems Ltd in Pakistan and supplies the QED and Huberg leak detection range with local technical support. Contact us with your gas, application and quantity for a quotation.
Need to find and classify gas leaks on your network or site in Pakistan? Contact Tetracon with the gas, the application and the number of instruments. You can also browse the Metrex 2 product page and the QED Environmental Systems manufacturer page, or the full product catalogue and all manufacturers.