FGD14 Safe Area Gas Detector
Safe-area fixed detector for oxygen and toxic gases with remote visual and audible alarm unit.

Ex db infrared gas detector head for direct replacement of oil & gas industry pellistors.
The FGD5/6-IR is an explosion-protected, ATEX/IECEx approved fixed infrared gas detector designed for direct replacement of pellistors in oil & gas applications. Constructed from 316 stainless steel and featuring remote gas test capability, it offers a 5-year MTBF, minimal maintenance, a selectable rising or falling output signal and an optional weather guard.
An NDIR infrared sensor measures hydrocarbon gas (methane) and produces a mV signal proportional to gas level (15–30 mV / % CH4), so the head can be wired to industry-standard pellistor control panels. It is self-heating to protect against obscuration and uses no mirrors, lenses or separate heaters.
| Sensor Type | NDIR infrared |
|---|---|
| Gas Types | Hydrocarbons (no response to hydrogen) |
| Measurement Range | 0–100 % LEL (5 % vol CH4) or 0–100 % vol CH4 |
| Resolution | 1 % LEL or 1 % volume (CH4) |
| Output Signal | 15–30 mV / % CH4 |
| Operating Voltage | 3.2–7.5 V DC at detector head |
|---|---|
| Max. Short-term Overload | 24 V DC |
| Operating Current | 160–250 mA (200 mA version) or 250–350 mA (300 mA version) |
| Operating Temperature | -20 to +50 °C |
|---|---|
| Humidity | 0–95 % RH non-condensing |
| IP Rating | Enclosure IP66, sensor IP65 |
| Material | Sensor body 316 stainless steel; weather guard 304 SS & nylon 66 |
|---|---|
| Size | 94 mm long × 50 mm dia.; 170 mm with weather guard |
| Mounting | M20 × 1.5 thread |
| Weight | 1 kg including weather guard |
| Code | II 2G Ex db IIC Gb, Zones 1 & 2 |
|---|---|
| Certificates | CSANe 22ATEX1187U, CSAE 22UKEX1395U, IECEx CSAE 23.0010U |
All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.
Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.
Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.
Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.
Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.