Condumax II Hydrocarbon Dew-Point Analyzer
Fully automatic, chilled-mirror hydrocarbon and water dew-point analyzer for natural gas quality.

Intrinsically safe transmitter for trace moisture in hazardous-area gases and non-polar liquids.
The Easidew I.S. is a dedicated intrinsically safe dew-point transmitter certified for measuring trace moisture and water dew-point in flammable or explosive gases and a wide range of non-polar liquids. It carries global hazardous-area certification (IECEx, cQPSus, ATEX, UKCA), making it suited to compressed-air drying, medical gas, CNG stations and natural-gas moisture duties inside classified areas.
Michell’s ceramic metal-oxide moisture sensor changes capacitance in proportion to adsorbed water vapour. A 2-wire loop-powered circuit linearises and temperature-compensates the reading, outputting a 4-20 mA signal scaled to dew point or ppmV moisture content; the sensor and electronics are packaged to intrinsically safe Ex ia standards for direct installation in Zone 0 / Division 1 areas.
| Measurement Range | −100 to +20°C dp (−110 to +20°C dp variant available) |
|---|---|
| Accuracy | ±2°C dp |
| Response Time | 5 min to T95 (dry to wet) |
| Repeatability | 0.5°C dp |
| Calibration | Traceable 7-point certificate |
| Output | 4-20 mA, 2-wire loop-powered |
|---|---|
| Supply Voltage | 12–28 Vdc |
| Load Resistance | Max 250Ω @12V (500Ω @24V) |
| Current Consumption | 20 mA max |
| Compliance | CE & UKCA |
| Operating Temp | −40°C to +60°C |
|---|---|
| Compensated Range | −20°C to +50°C |
| Operating Pressure | 52.5 MPa (525 barg) max, 2x overpressure to 900 barg |
| Flow Rate | 1–5 Nl/min (sample block); 0–10 m/s direct insertion |
| Housing | 316 stainless steel |
|---|---|
| Ingress Protection | IP66 (NEMA 4) |
| Process Connection | 5/8" UNF, G1/2" BSP or 3/4" UNF |
| Electrical Connection | Hirschmann GDS series (DIN 43650-C) |
| Weight | 150 g |
| ATEX / UKCA | II 1 G Ex ia IIC T4 Ga (−20 to +70°C) |
|---|---|
| IECEx | Ex ia IIC T4 Ga (−20 to +70°C) |
| North America | cQPSus Class I Div.1 Groups A-D T4; Class I Zone 0 AEx/Ex ia IIC T4 Ga |
All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.
Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.
Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.
Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.
Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.