OptiPEAK TDL600 Moisture in Natural Gas Analyzer
Next-generation TDLAS analyzer for automatic online moisture measurement in variable natural gas and biomethane streams.

Fully automatic, chilled-mirror hydrocarbon and water dew-point analyzer for natural gas quality.
The Condumax II provides continuous, automatic on-line measurement of hydrocarbon dew point in natural gas using the patented "Dark Spot" direct chilled-mirror technique, delivering objective, highly repeatable results with 0.5°C accuracy. An optional Ceramic Metal-Oxide Moisture Sensor adds simultaneous water dew-point measurement. Housed in a compact explosion-proof enclosure, it is suitable for natural gas containing up to 20% hydrogen with no modification, and both indoor and outdoor sampling systems are available as standard for gas up to 138 barg.
A thermo-electrically cooled mirror surface is continuously monitored by an optical sensor; as the mirror is cooled, hydrocarbon condensation forms a detectable "dark spot" at the exact dew-point temperature, which the self-cleaning system captures with high repeatability. The optional ceramic metal-oxide sensor independently measures water dew point in parallel, and both readings are output via Modbus RTU for integration with plant control and custody-transfer systems.
| Parameters | Hydrocarbon Dew Point (optional Water Dew Point) |
|---|---|
| Accuracy | 0.5°C (hydrocarbon dew point) |
| Detection Principle | "Dark Spot" direct chilled-mirror technique |
| Sample Pressure | Up to 138 barg |
|---|---|
| Sampling Systems | Indoor and outdoor, standard or custom-engineered |
| Hydrogen Compatibility | Up to 20% H2, no modification required |
| Communication | Modbus RTU |
|---|---|
| Hazardous Area Certification | IECEx, ATEX, UKCA, cQPSus, GOST Ex |
| Enclosure | Compact explosion-proof |
All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.
Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.
Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.
Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.
Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.