Zirconia Oxygen Analyzer System

Zirconia (ZrO2) oxygen measurement system: 0.1–25% or 0.1–100% O2, 0.5% O2 accuracy after calibration.

ModelOXY-LC board + O2S-FR-T2-18BM sensor
SKUSST-OXY-LC-ZR
CategoryOxygen & Combustion Analyzers

Key Features

  • Fast response zirconium dioxide (ZrO2) sensor with the OXY-LC interface board
  • Long life, non-depleting technology
  • Integral heating element
  • Linear output signal
  • 4–20 mA or 0–10 VDC analogue output, or RS485 Modbus RTU
  • Probe lengths 28 mm, 45 mm or 55 mm; M18 x 1.5 screw mounting

Overview

A complete oxygen measurement system consisting of a fast-response zirconium dioxide (ZrO2) sensor and the SST OXY-LC oxygen sensor interface board. It measures 0.1–25% or 0.1–100% O2 on the analogue output (0.1–100% O2 over Modbus RTU) with an accuracy of 0.5% O2 after calibration, and needs no reference gas.

Working Principle

A zirconium dioxide (ZrO2) sensor with an integral heating element (pump impedance < 6 kΩ at 700 °C) is driven by the OXY-LC interface board, which converts the measurement into a linear O2 output. The technology is long-life and non-depleting, and no temperature stabilisation is needed.

Benefits

  • No reference gas required
  • No need for temperature stabilisation
  • Variety of probe mounting positions available

Technical Specifications

Sensor
TypeZirconium dioxide (ZrO2)
Range (analogue output)0.1–25% O2 or 0.1–100% O2
Range (Modbus RTU)0.1–100% O2
Accuracy after calibration0.5% O2
Output resolution0.01% O2
Response time (10–90% step)< 4 s
Initial warm-up (till stable output)5–10 min
Electrical
SupplyRS485 variant 8–28 VDC; analogue variants 20–28 VDC
Supply current600 mA max. at 24 VDC; 1.2 A max. at 12 VDC
Analogue output4–20 mA (load 600 Ω max.) or 0–10 VDC (load 10 kΩ min.)
Digital outputRS485 (Modbus RTU)
Start-up delay (heater warm-up)60 s from OFF to ON; 20 s from Standby to ON (RS485 only)
Process
Gas temperature-100 °C to +250 °C
Gas flow rate0–10 m/s (with baffle fitted)
Operating pressure260–1260 mbar absolute
Mounting threadM18 x 1.5
Ordering
Interface boardsOXY-LC-485 (Modbus RTU), OXY-LC-A25-455 / OXY-LC-A100-455 (4–20 mA), OXY-LC-V25-455 / OXY-LC-V100-455 (0–10 VDC)
SensorsO2S-FR-T2-18BM-A (55 mm), -B (45 mm), -C (28 mm)

Downloads

Datasheet (PDF)PDF

Frequently Asked Questions

What warranty is offered on this product?

All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.

Do you provide installation and commissioning?

Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.

Are spares and calibration available locally?

Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.

How long is the typical lead time?

Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.

Request a Quote — Zirconia Oxygen Analyzer System

Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.