Home About Us Manufacturers Products Services Clients Downloads Blog Guides FAQ Contact
RB RB Technologies

FiNCORE AFiH In-situ Combustion Oxygen Analyzer (Medium/High Temperature)

FiNCORE AFiH in-situ zirconia O2 + COe analyzer for medium/high-temperature flue gas up to 1500 °C, with remote transmitter up to 50 m away.

ModelAFiH
SKURB-AFIH
CategoryOxygen & Combustion Analyzers

Key Features

  • Measured gas temperature up to 1500 °C
  • O2 range adjustable 0–1 % up to 0–50 %; COe 0–1,000 up to 0–9,999 ppm
  • Accuracy ±0.5 % of measurement or 50 ppm O2 (no reducing gas)
  • 2 × 4-20 mA NAMUR + RS485 Modbus RTU, 2 dry-contact inputs, 3 relay outputs
  • 24 V DC or 115–230 V AC, average 7 W
  • Configurable filter holder (60/100 mm SS316L), calibration set and display cabinet
  • Direct, by-pass or semi-extractive sampling tubes, flue 200 mm to 5 m

Overview

FiNCORE AFi medium/high-temperature in-situ O2 analyzer for process temperatures up to 1500 °C with remote monitoring for boilers, furnaces, biomass, incinerators and dryers.

Working Principle

A heated zirconium-oxide sensor, regulated at 600–800 °C by an S-type thermocouple, measures O2 against an air/gas reference according to the Nernst law, with a second channel for COe/pRed unburnt compounds. The sensor is temperature-regulated and fully compensated, so performance is unaffected by process temperature.

Benefits

  • Combustion efficiency and safety control for refinery heaters, petrochemical furnaces, boilers, glass and metal-treatment furnaces
  • Low-maintenance probe design with fast response (T60 < 15 s)
  • Built-in O2/O2 redundancy options for lower maintenance/calibration

Technical Specifications

Measurement
PrincipleZirconium oxide sensor (Nernst), O2 % and COe ppm
O2 RangeAdjustable 0–1 % up to 0–50 %; MDQ 0.01 % O2
COe RangeAdjustable 0–1,000 up to 0–9,999 ppm; MDQ 10 ppm
Accuracy±0.5 % of measurement or 50 ppm O2 (COe < 10 ppm); ±0.75 % or 0.05 % O2 in oxidizing flue gas
Measured Gas TemperatureUp to 1500 °C
Measured Gas Pressure-0.5 to +0.5 bar
Outputs & Power
Analog2 × 4-20 mA NAMUR (max 1000 Ω)
DigitalRS485 Modbus RTU
Power24 V DC or 115–230 V AC; average 7 W, up to 9 W
Warm-up< 10 min
ResponseT60 < 15 s at sampling port; T60 < 4 s at calibration port
I/O2 isolated 24 V DC dry-contact inputs; 3 × 230 V AC relay outputs
Calibration
Intercept / Slope gas20.9 % O2 (instrument air) / 1.0 % O2
COe gas2 %vol O2 + 250 ppm CO + 25 ppm H2

Downloads

Datasheet (PDF)PDF

Frequently Asked Questions

What warranty is offered on this product?

All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.

Do you provide installation and commissioning?

Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.

Are spares and calibration available locally?

Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.

How long is the typical lead time?

Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.

Request a Quote — FiNCORE AFiH In-situ Combustion Oxygen Analyzer (Medium/High Temperature)

Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.