FGD14 Safe Area Gas Detector
Safe-area fixed detector for oxygen and toxic gases with remote visual and audible alarm unit.

ATEX/IECEx flameproof fixed detector for oxygen, toxic and flammable hydrocarbon gases.
The FGD10A is an explosion-protected, ATEX and IECEx certified flameproof (Ex d) fixed gas detector for oxygen, toxic and flammable hydrocarbon gas detection in potentially explosive atmospheres. A magnetic pen-operated menu allows calibration and configuration through the display window without opening the flameproof enclosure, and the unit is available with or without an integral LCD display.
A single plug-in sensor — NDIR infrared, catalytic pellistor or electrochemical — measures the target gas inside the flameproof enclosure. Readings are shown on the 4-digit LCD and output as a 4–20 mA signal (10-bit) and RS232 (19200 baud), with three control relays for Alarm 1, Alarm 2 and Fault. Calibration and configuration use a magnetic pen through the display window, without removing the cover.
| Code | II 2 G Ex db IIC T6…T4 Gb, Zones 1 & 2 |
|---|---|
| Certificates | Sira 08ATEX1031X, IECEx SIR 08.0009X, CSAE 23UKEX1031X |
| Input Voltage | 12–24 V DC |
|---|---|
| Input Power | 5 W maximum |
| Analogue Output | 4–20 mA (10-bit resolution) |
| Communications | RS232, 19200 baud |
| Relays | 3 (Alarm 1, Alarm 2, Fault), 3 A 250 V AC |
| Sensor Types | NDIR infrared, electrochemical or pellistor |
|---|---|
| Example Ranges | CO2 0–500 ppm to 0–100 %; CO 0–50/100/1000 ppm; H2S 0–50/100 ppm; O2 0–21/25 %; flammable 0–100 % LEL or 0–100 % vol |
| Body Material | Pressure die-cast aluminium or 316 stainless steel |
|---|---|
| IP Rating | Enclosure IP68, sensor IP65 |
| Dimensions | 190 × 145 × 127 mm |
| Weight | 1.75 kg (2 kg infrared) |
| Cable Entries | 2 × 20 mm or ½" / ¾" NPT |
| Operating Temperature | Typically -20 to +50 °C |
All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.
Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.
Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.
Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.
Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.