Zirconia (ZrO2) oxygen analyser with probe: 0.1–25% or 0.1–100% O2, 4–20 mA / 0–10 VDC and RS232 outputs.

ModelOXY-Flex
SKUSST-OXYFLEX
CategorySensors & Sensor Cells

Key Features

  • High accuracy linear output
  • Externally triggered automatic or manual calibration
  • Can be calibrated in fresh air (20.7% O2) or to any other known O2 concentration
  • Selectable output filtering: adaptive, fast and dynamic, or slow and stable
  • 4–20 mA or 0–10 VDC analogue output plus RS232 digital output
  • Probe lengths 220 mm or 400 mm

Overview

The SST OXY-Flex is a zirconium dioxide (zirconia) oxygen analyser with an integral probe, for gas temperatures from -100 °C to +250 °C at the probe tip (-100 °C to +400 °C with the high-temperature option). It gives a high-accuracy linear output, needs no reference gas, and can be calibrated in fresh air (20.7% O2) or to any other known O2 concentration.

Working Principle

A zirconium dioxide (ZrO2) sensing element measures the partial pressure of oxygen (PPO2) in the measurement gas. Because it measures partial pressure, a change in barometric pressure from that present during calibration causes a proportional readout error (e.g. a 1% rise in pressure raises a 21% O2 reading to 21.21% O2). A cycling 3.3 VDC logic output follows the O2 sensor pump cycle for diagnostics.

Benefits

  • No reference gas required
  • Cycling 3.3 VDC logic output allows direct monitoring of the O2 sensor pump cycle for diagnostic purposes

Technical Specifications

Sensor
TechnologyZirconium dioxide (ZrO2)
Range (analogue output)0.1–25% O2 or 0.1–100% O2 (jumper selectable)
Range (RS232 output)0.1–100% O2
Accuracy after calibration1% O2
Repeatability after calibration0.5% O2
Response time< 15 s
Warm-up time60 s (prior to sensor operation)
Output stabilisation time~180 s
Electrical
Supply24 VDC ± 10%
Supply current< 1 A operating, < 2 A start-up (at 24 VDC)
Analogue output4–20 mA (load 600 Ω max.) or 0–10 VDC (load 10 kΩ min.)
Digital outputRS232
Output resolution0.01 mA / 0.01 V / 0.01% O2 (RS232)
ConnectorAmphenol Ecomate C016 30C006 100 12; mating Binder 99-4218-00-07 supplied
Operating Conditions
Housing temperature-10 °C to +85 °C (storage and operating)
Gas temperature (probe tip)Standard -100 °C to +250 °C; High -100 °C to +400 °C
Gas flow rate0 to 10 m/s
Permissible acceleration5 g repetitive, 30 g incidental
Cautions
Low O2Prolonged operation below 0.1% O2 can damage the sensing element
SiliconeZirconia sensors are damaged by silicone vapours (e.g. from RTV rubbers and sealants)

Downloads

Datasheet (PDF)PDF

Frequently Asked Questions

What warranty is offered on this product?

All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.

Do you provide installation and commissioning?

Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.

Are spares and calibration available locally?

Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.

How long is the typical lead time?

Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.

Request a Quote — OXY-Flex Zirconia Oxygen Analyser

Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.