GPR-7500 (A)IS Online H2S Analyzer
Online ppm hydrogen sulphide analyzer with electrochemical sensor, certified for flammable gas streams.

BTU & hydrocarbon content analysis for natural gas processing and custody transfer.
The Galvanic AccuChrome GC4 performs Btu and constituent analysis of natural gas for custody transfer, process optimization during fractionation, and 40 CFR 60 Subpart JA flare-gas emissions monitoring. Auto calibration and validation enable fully hands-off, stand-alone operation, with all components field-serviceable for fast, low-cost maintenance.
Sample gas is separated by gas chromatography and measured with a thermal-conductivity detector housed in an airless heat-sink oven. Low-maintenance injection valves and a detector that resists burnout from carrier-gas loss or corrosive H2S keep the analyzer running reliably in harsh field conditions.
| Compounds | Btu, SG, Wobbe, mole % (O2, CO, C6+–C12+, N2, CH4, CO2, ethane, H2S, propane, butanes, pentanes, H2) |
|---|---|
| Accuracy | ±0.25 % Btu/scf per 1,000 Btu/scf or ±0.5–2 % FS (application specific) |
| Sensitivity | 200 ppm ≤ C7+ |
| Detector | Thermal conductivity (TCD) |
| Analysis Time | 4 minutes (application specific) |
| Carrier Gas | Helium or hydrogen at 4.1 bar, 20 cc/min |
| Analog | 4 × 4–20 mA out, 3 × 4–20 mA in |
|---|---|
| Digital | Modbus TCP/IP, RS232 or RS485; 4 × SPDT relays; 4 discrete inputs |
| Power | 24 VDC or 90–240 VAC, 100 W start-up / 50 W running |
|---|---|
| Ambient | -20 to 60 °C |
| Enclosure | Stainless steel Type 4/4X IP66 (Div 2) or cast aluminium Type 4 (Div 1 / Zone 1) |
| Area Classification | Class I Div 2 / Div 1 Groups BCD T3; II 2 G Ex db [ia Ga] IIB+H2 T3 Gb |
All Tetracon-supplied instruments carry the original manufacturer warranty (typically 12–24 months) plus first-line local support from our Islamabad service centre.
Yes. Our manufacturer-trained engineers offer on-site installation, commissioning and startup training anywhere in Pakistan.
Common spares are held in local stock. Calibration is available at our lab or on-site with NIST-traceable reference standards.
Stocked items ship within 3–5 working days; engineered configurations typically 6–10 weeks depending on manufacturer schedule.
Complete the form below and one of our engineers will respond within 1 working day with pricing and lead time. Prefer email? Contact our sales team.